Notes de Rachel/Interns, Summer 2018 (51 notes)/Week 8
Jump to navigation
Jump to search
Notes de Rachel / Interns, Summer 2018 (51 notes)
10.09.2018
- Cleaned up the Git
- Looked at the Triton contaminants (still not dry completely !)
- See the design of the chip (Anna tried to 3D print it friday)
- Redo the experiments from last week (agar agar, distilled water)
- Retrieve the EDTA from the DMF
- Make Triton
- Which one?
- Lysis buffer: http://cshprotocols.cshlp.org/content/2009/11/pdb.rec12004.full
- Extraction buffer: http://cshprotocols.cshlp.org/content/2011/3/rec12422.full
- Both of the above triton solutions are for various protocols...
- -> 10% Triton for making the PK buffer is simply 1:10 dil of 100% in sterile water.
- Make new materials for comets (PK Buffer and Triton)
- With sterile and distilled water
- Redo the experiment (20180904 comet control vs distilled vs agar-agar)
- See 20180910 comet control vs distilled vs agar-agar for the new note
- We didn't do the "Double distilled" condition, as we didn't have enough cells to make enough pads
11.09.18
- Microscope at 14:00
- In case it is necessary, possibility to gather sterile water?
- From yesterday: there is a very low amount of PK+
- No slimy thing with PK+ compared to last week, so hopefully no contaminants
- Milky aspect of PK buffer disappeared in some wells
12.09.18
- Test of new dyes on the pads of yesterday: food colorant and Lawsonia inermis
- See 20180910 comet control vs distilled vs agar-agar
- Not very good, we cannot see anything (no cell and no DNA)
- Test of the new chip:
- Volume
- Volume of the wells = 20 x 20 x 1.5 = 600 ul
- Test of the wells, with glass lid at the bottom, with volumes of 250, 500, 600 and 850 ul
- Which is good is that the water does not spread and stay "together"; with 600 ul in covers entirely the well and with 850 ul, the water makes a bump, but does not spread to the other wells
- BUT
- Leakage
- After some time, one well leaked and soon after a second one too. Once it leaked, it won't stop.
- After that scotch was put to try it
- Scotch
- First glass lids weren't put. The liquid did not spread on the bottom of the well, BUT id did not leak! When we wanted to put the glass lids, they couldn't reach the bottom of the well, because of the liquid.
- Then we discarded the liquid and put first the glass lids.
- We put again the liquid:
- 1st well went well
- 2nd, we detached the scotch and the liquid leaked again. The glass lid did not seal the hole enough.
- 3rd, the glass lid went up, on the liquid. But there was no leakage.
- Pads
- Not easy to pour and the gel goes out of the same hole that we pour him in; we have to pour on both holes to make pads.
- Once it is solidified, the pads are a bit difficult to take out of the "sandwich" of plates, but easy to put on the glass lids on the chip
- CAREFUL: sometimes, once we pour liquid on the well, the glass lid goes up and floats on the liquid
- Volume
13.09.18
- Test of the OpenComet plugin, not very conclusive
- Prepare for microscope tomorrow
- Make 5X TBE
- We have 1.906 g of Boric Acid (in powder) and 16.736 g of Tris Base? The latter is to confirm. It's Tris!
- How to prepare it? In sterile or bi distilled water or in physiological solution?
- Sterile, it is better, if we want to reuse this 5X TBE
- Make Tris:
- For 0.5M, we need 121.135 g/L
- I put 3.028 for 50 ml
- BUT, this is Tris Base. Therefore I put 3.028 g in 30 ml and test 5 ml of this solution with the pH-meter.
- Make pads with the chip
- Parameters we want to test
- Sterile water as the negative control and physiological solution as a new test
- Protocols
- 3 experiments:
- Everything made with sterile water (TBE, Saline, PK Buffer etc). Electrophoresis will be made out of the chip (1) or within the chip (2).
- Finally, we will make as much as possible compounds made with physiological solution (3).
- Parameters we want to test
- PK+
- Can it still work after several days at room temperature? Nope
- Do we have some left? Yep, there is still some in the fridge.
- Make 5X TBE
14.09.18
- Microscope again? In order to test:
- the "Double Distilled water" condition (where the Triton and the 5M NaCl are made of distilled water)
- the physiological solution (5 x 5ml)
- some pads made with the 3D printed chip