Notes de Rachel/Covid-19 LAMP tests (46 notes)/27102020 blinded samples RNA extraction
Notes de Rachel / Covid-19 LAMP tests (46 notes)
use Monarch kit again
A, B, C samples
saliva and swab tests and columns
100ul saliva + 100ul DNA/RNA protection reagent
from swab tubes, get 100ul of liquid back (not really!) add 100ul water...
A-C1 -swab liquid
A-C2 -saliva
wearing gloves and mask etc!
carefully out of bags and another etoh wipe before labeling and manips.
C2 saliva is the gooey-est...
use 100ul water to get swab stuff down from edge where squashed (15ml conical for that) - end up with a bit less than 200ul, but go on with 400ul RNA Lysis Buffer, then onto gDNA removal column
let sit there a minute, then spin 1 min
save flowthrough - add 1vol EtOH... to RNA purification column
washes x2 then elute with 25ul nucl free water.
to Extract box in freezer
For cheek cells, take 0.5ml of settled cells and make smears and pellet the rest.
Aa and Ab same (save rest at RT o/n and make Ac slide)
(same for B and C cells)
A has most cells harvested...
to freezer in bag
extra care with these!
flamed slides should be safe...
will have 3rd after o/n too - to see whether micronucl ratios change after o/n in saline RT
Only 3 columns left for the monarch kits but lots more reagents!
Hope virus would be opened by the lysis buffer! the DNA/RNA Protection reagent is thought to already inactivate the virus too..