Notes de Rachel/Covid-19 LAMP tests (46 notes)/09072020 primers aliquoting

From Hackuarium
Jump to navigation Jump to search

Notes de Rachel / Covid-19 LAMP tests (46 notes)

even though the delivery day says 30June, the DHL package only arrived today . days from Munich to Geneva, it felt like!

Includes FAM FIP for NM and HEX for RNaseP set and appropriate quenchers!
These 4 tubes in a black bag.

Check volumes from packing list, all ok yields? all over 30nmols some even over 70nmols...
so, seems like it - only the 2 quenchers with 3' BHQ1 are about 300ul for 100uM

Start hood, and clean,

run 15mins and clean again.
Get ice ready...
Fresh clean water in 50ml conical, from bottle from BioConcept, under hood.
Prepare tubes for the aliquoting, have also plastic bags for aliquots.

  1. Spun in the microcentrifuge to make sure that the lyophilised contents aren't lost upon opening.
  2. The appropriate volume of Sterile water for making a 100uM solution (as written on the shipping documents) should be added. 
  • double check all labels and check off list!!

prepare bags
Tagged ones (FAM_NM_FIP, antiNMFIP-Quench, and HEX_RNAseP_LF, and RNAseP-Quench)
to dark bag again. x5 tubes for aliquots each
plus
OL- OrfLamb  set
18S set

E16S - Entero16S set
F3/B3, FIP/BIP, LF/LB
and PCR primers 16S-671 and 16S 672.
and tubes (label)
and to put in same as first set box for original tubes.

  1. Wait 5 min at RT

  2. Vortex for about 1 min full speed

  3. Wait again 5 min

  4. Check for complete resuspension, can tap and shake

quick spin, to make sure liquid is not in caps, then all to ice.
Aliquot suitable volumes for the application.
Normally, would make about 5+aliquots of the 100uM (as possible)
- only got x2 for now and
saved the initial tubes in the separate freezer box. (tagged ones in black bag still)
Store at -20oC - big freezer special drawer.

7) to add to inventory page. doc -still to do! and to add link here

  1. optional *  done today for 

Can prepare a mix for 35 reactions of 25ul of the usual LAMP primer mix, including all  primers (FIP/BIP/F3/B3/LB/LF), is made as follows, per 25ul reaction:

0.4ul FIP and BIP (40 µl)

0.2ul LB and LF (20 µl)

0.1ul F3 and B3  (10 µl)
Final Volume: 140ul
So,
this comes out to
28uM FIP/BIP
14.2uM LB/LF
7uM F3/B3
1.4ul per 25ul reaction gives final concentrations of about
1.6uM FIP and BIP,  0.8uM LB and LF, and 0.4uM F3 and B3
(in some cases this can probably be adjusted *assay optimisation - down to 0.4 for LB/LF and to 0.2 for F3/B3 for NM was good... to finish result sum to date!)

9)  place the quality certificate datasheets in a safe place (clear lab folder in desk)