Notes de Rachel/Covid-19 LAMP tests (46 notes)/07082020 Multiplexes NMFAM-RPHex

From Hackuarium
Jump to navigation Jump to search

Notes de Rachel / Covid-19 LAMP tests (46 notes)

To find out if the 10min extra for RTx was necessary for the good result with Bst2.0
(also repeat with BO again)
First clean with 10% bleach. Then check that I have enough primers for all sets of tubes (make more if needed) and RNAs
 

Master mixes for 8 rxn tubes  (1,2 - water, 3,4 BEI RNA 100, 5,6 cell RNA, 7,8 BEI RNA 100 + cell RNA) 
A: BO +RTx and RNAsin 
B: Bst2.0 + RTx and RNAsin
x2 (so 4 8-tube strips: A+ and B+ with extra 55degree 10min)

Master Mixes for tagged primers:

2.0ul 10x buffer -  Isothermal buffer for Bst2.0           (x17 for all components for the 16 reactions)                                                                                                                                          (34ul)
1.12ul* tagged primer mix                                       (19ul + 19ul)         (DOUBLED for multis)                             
1ul extra MgSO4, 100mM (for 5mM more - 7mM final in reaction)       (17ul)      
2.8ul dNTP, 10mM                                                                                    (47.6ul)
0.8ul Bst2.0 (8units) or        BstLarge Fragment                             (13.6)
for both master mixes RTx                                                       (13.6)
RNAsin (40units/ul) (0.5ul/reaction)                         (8.5)
water + sample to 20ul final   (say 2ul of RNA or water per reaction)
18-(all components above -doubleprimers) 7.86x17= 134

NM fluor primer mix _FAM-NM*FIP + RNaseP fluor primer mix. _hex-RP*LF  

Both quenchers 8.8ul for NM-FIP quench +4.4 for RP-LF quench, for water  -> 120.5ul

        • For pcr machine - start with 10min at 55 degrees for *+* tubes, to give RTx a better chance to work (since low!)****
        • then put 0 tubes in too.****
        • 1st picture after that + 5min of 65oC****
        • always do A, A+, B, B+ for order of pics of tubes****
        • by 35 min all the B+ + look good!****
        • saw diff of 100copies - came up after the cell RNA signal today.****
        • is the diff more than 10min, without the RTx at 55degree step??****