Notes de Rachel/Covid-19 LAMP tests (46 notes)/02092020. Tatiana doing E16S

From Hackuarium
Jump to navigation Jump to search

Notes de Rachel / Covid-19 LAMP tests (46 notes)

to give the latest E16S primer set another try -
 - use different bacterial lysates also?

From last primer aliquoting (09072020) did make up 'standard mix' which gives final concentrations:
1.6uM FIP and BIP,  0.8uM LB and LF, and 0.4uM F3 and B3. - do first tests with these
E16S - Entero16S set
Again just try Bst2.0 + RTx/RNasin (+/- RTx/RNasin for the E16S and 18S)
x2 water, x2 bact lysate1, x2 bact lysate 2, x2 bact lysate 3, x2 cell RNA and finally x2 'swabs' - wipe door knobs and light switches with paper towel, into 200ul h2O 95degrees 5min)

for bact lysate 1 again use the dilution of 11July2020 #1 (seq#21 from 22july results) SVT met green lysate (E coli) as Bact Lysate (to dil 1/5... 8ul in 32ul h20 - still pink from Levine color! )
for bact lysate 2 seq#24 from 22july results) Enterobacter (pink middle giant gooey VNX) diluted 1/10
for bact lysate 3 seq #25 - Cronobacter sakazaki (also E.coli hit) met green Venoges colony... diluted 1/10

Master Mixes for realtime amp data:  5 MM for 12 reactions each
2.0ul 10x buffer -  Isothermal buffer for Bst2.0           (x13 for all components for the 8 reactions)                                                                                                                                          (26ul)
1.12ul* primer mix                                       (14.6ul)                                      
1ul extra MgSO4, 100mM (for 5mM more - 7mM final in reaction)       (13ul)      
2.8ul dNTP, 10mM                                                                                    (36.4ul)
0.8ul Bst2.0 (8units) or                                                                      (10.4)
(for some master mixes RTx and RNAsin                                                      (10.4 + 6.5)  OOPs RA had Tatiana Put these in B master mix!
1.6 ul SYBR-safe diluted 1/250 from stock solution.           (20.8) 
water + sample to 20ul final   (say 2ul of lysate, RNA or water per reaction)
         WATER  A rxns (with RTx and RNAsin) = 7.38x13 =95.94    for BEI RNA dilute fresh 1000copy 1/10, so 100copies/ul.  -smaller volume only about 60% for last tube
for 1A:200 copies/ rxn 7,8,9,10, (for 16S and E18S 9,10 100copies with appropriate 2nd RNA for mix)
                        B rxns (2B/3B) = 8.68x13=112.84.  had this vol for B!
put 1ul of each sample as above
10min 55degrees for RTx to start! change conditions on Prism
Again- Approximately Isothermal conditions, so get good traces:
55 10min, 64 1min, then 'cycle' 10s 65 and 1:50s 64. (for imaging every 2 min)
do 35 cycles again with dissociation protocol clicked and 60 degrees...

Results

best was number 6a bact 2 up by cycle 11 (25min)