Notes de Rachel/Interns, Summer 2018 (51 notes)/Week 7
Revision as of 09:45, 26 November 2026 by Zaphod (talk | contribs) (Adding Category:Note (batch edit via API))
Notes de Rachel / Interns, Summer 2018 (51 notes)
- Test new conditions for the comet assay
- Begin the presentation for the 26.09.18
- Microscope? Yup
03.09.18
- Comet assay preparation for the experiments of 05.09.18 :
- With the 3.6 ml of EDTA (from last week), we can make 16 ml of PK Buffer, which is the usual volume for our reactions (we don't have to worry about TBE, which were already done): roughly 10 wells
- Tomorrow, we will try:
- 3 wells with sterile ingredients (Control)
- 3 wells with distilled water (from Migros) (1st test)
- 3 wells with sterile agar-agar gels (2nd test)
- Uploading of the photos of the 23.08.18
- Continuation of the microchip:
- Laser engraving of the paper layer (3 round holes, on a typical printer paper)
- 17.67 ul of volume for each
- This paper tends to absorb the gel
- We redo the thin layer that will give the pads their thickness, with plastic and with a "plasticised paper".
- Much better, there is no diffusion of the gel in these layers
- Laser engraving of a plastic plate, to pour the gel
- Test to pour agarose gel
- Very poor results, the gel can not spread to fill the entire hole: either the volume (17 ul) is too low, either the gel is too viscous (it is stuck in the tip of the pipette), either the bottom plate was to cold. Plus, the paper absob
- I added 7.5 ml of sterile saline, in order to liquefy the gel --> it is better
- Idea: not to stick to the exact volume of the needed pad (17 ul), but have a large volume (150 ul) and let the gel go out from the second hole
- Laser engraving of the thick plastic plate, where the pads will be transfered and the electrophoresis occurs
- Many difficulties, but finally it should work:
- 3.5 mm deep wells, where we will put the pads and do the washes
- 3.5 mm deep wells, to put the electrodes, for the electrophoresis
- 1.2 mm for the "Big bassin", where the electrophoresis liquid will embrace the pads
- Many difficulties, but finally it should work:
- Laser engraving of the paper layer (3 round holes, on a typical printer paper)
04.09.18
- Microchip
- New comet assay
- Make agarose and agar-agar, using sterile and bidistilled water
- Checking the protocols
06.09.18
- Redid some schemes for the chip
- Test & calibration of the pH meter
- First the pH of tap water was 7.45
- After having modified the the slope and the offset of the pH meter er did again the testing
- Tap water at 6.95 - 7
- Control liquid of pH 7 at 7
- Control liquid of pH 4 at 4.3
- Changed the slope, until it was pH 4.00
- Control liquid of pH 7 at 7
- Bidistilled (from jerricane) and sterile (from lab grade US Siemens) water at pH 8.5, this was strange
- But one strong acid had a pH of 1.67, which was correct
- Washing with tap water many times, until the pH was at 7
- Bidistilled water and sterile water this time had 6.3 and 6.1 respectively
- Storage solution (KOH ?) has a pH that slowly went from of 5.81 to 5.9 to finally 6.15
- Checked the PK+ buffer from the experiment that did not work, it is contaminated by bacteria
- From the pictures we thought that something looked like soap, Rachel thus thought about checking Triton and Triton looked contaminated !
- We then dried a plate with the contaminant to observe it tomorrow
07.09.18
- Meeting with Roger to be updated about current trends for programming
- Websites:
- His (professionel): http://mwshovel.pythonanywhere.com/
- His (personnal): http://www.hammerdirt.ch/
- Python: https://www.python.org/
- Jupyter: http://jupyter.org/
- Github: https://github.com/hammerdirt
- Websites:
- Work again on the schemes for the chip
- Testing of the pH meter
- When starting the pH meter with the storage solution, it had a pH of 6.62
- Once the storage solution was taken out, salt precipitates were observed on the probe
- pH of Tap Water (TW) : 7.65
- pH of the solution at pH 7: 7.00 - 7.01 (the result went fast)
- pH of TW: 7.6 - 7.65
- pH of solution at pH 4: 3.99 - 4 (fast)
- pH of TW: 6.5 - 7.64
- pH of bidistilled water : 8.65 -> 6.90 slowly
- https://www.elgalabwater.com/blog/water-purity-and-ph-not-simple-you-think
- Worked on the wiki for the chip
- Observations of the contaminant of the triton
- It did not dry during the night, so we put the plate again on the hot plate