  • Make the microscope:
  • Cut the blue and orange filters
  • Create a blue light using LED
  • Specificity: the halogen bulb is 30 W, the LED will have to be approximately 3 W
  • Ask Rachel:
  • Her device to see fluorescence (with orange and blue filters) is used for what kind of dyes?
  • SYBR Safe or FITC
  • --> Faire des contrôles de concentration avec différentes concentrations
  • What is the power of the LED used for this device
  • 1W
  • Reference for the LED and how to buy them; ask Urs
  • How to extract and assess the concentration of natural extracts? (like proteinase K)
  • Very difficult, it is not worth it, as we would have to use a spectrophotometer to to measure the activity of the protease, use oter (toxic) chemicals to make gels, etc etc
  • Buy a torchlight with white LED (InterDiscount has a powerful one)
  • Test it with normal cells stained with SYBR Safe
  • Buy filters
  • Idea: buy LED to mimic the specter of absorption and emission of SYBR safe
  • --> Done! Rachel had a fluorescin (FITC) that mimics the SYBR Safe
  • Redo comet assay
  • With distilled water (and not sterile water)
  • With normal protocol (sterile water)
  • Read about other DNA dye
  • With other frequencies of excitation
  • How to make single cells
  • 100 um canals and we need 30 - 50 um
  • Reading of BioMEMS

13.08.18

14.08.18

  • Test with SYBR safe: not very conclusive we did not see anything when we put the SYBR Safe. Hypothesis: the SYBR Safe cannot enter living cells
  • https://www.researchgate.net/post/How_does_SYBR_safe_compare_with_Ethidium_bromide 
  • Or more easily, we put a concentration of 1 in 1000, we should have put 1 in 10.
  • Kitchen Sink Proteinase K
  • Bromelain extraction from Pineapple: https://www.leaf.tv/articles/how-to-get-bromelain-from-a-pineapple/
  • Note: keep the dyes in the dark and in the cold in order to avoir degradation
  • https://bitesizebio.com/30453/flow-cytometry-fluorophores/
  • FITC is very visible with the DIY transilluminator, but NOT with the microscope, we don't know why. From the exterior of the microscope, we see that because of the blue light (of the LED), the slide emits light. But once we look through the lenses of the microscope, we cannot see anything from this light.
  • Hypothesis: The microscope has already filters, that block a part of the light. Therefore, we don't see much differences between area with or without FITC. --> Epifluorescence

can we test this more

15.08.18

  • Test with using:
  • A smartphone instead of the Raspberry
  • The white LED of the Foldscope
  • SYBR Safe:
  • Bound to nucleic acids, SYBR Safe stain has fluorescence excitation maxima at 280 and 502 nm, and an emission maximum at 530 nm. Stained DNA can be visualized and analyzed using imaging systems equipped with an excitation source in the UV range or between 470 nm and 530 nm
  • CAREFUL the SYBR Safe is very sensitive to the light. Because of the powerful blue light, the SYBR Safe was bleached.
  • Better when we use TBE with it (rather than saline)

16.08.18

17.08.18