Notes de Rachel/Covid-19 LAMP tests (46 notes)/18022021 - controls to make sure real time all still good

From Hackuarium
Revision as of 09:09, 26 November 2026 by Zaphod (talk | contribs) (Adding Category:Note (batch edit via API))
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Notes de Rachel / Covid-19 LAMP tests (46 notes)

     Want to test with realtime sybr safe runs to see if all is good again, so can finally test the ENAC sewage RNA sample (too bad they did not give negative too!)
     should try NM, OL, 18S and E16S primers against all 4 targets separately

     for OL want to use paper concentrations: 1.6uM Fip/Bip, 0.2 F3/B3  0.4 LF/LB  and 8mM Mg++
     Primer mix made fresh from 100mM stocks 20ul each FIP/BIP, 2.5ul each F3/B3 and 5ul LF/BF +15ul H2=used in master mix as below
     (so basically, this mix is 20x) maybe to do for all 3...   +RNASE Free Water so

        have extra LF/LB  vs. that for the NM primers (so 10ul each LF/LB  and otherwise as above- making final volume up to 60ul all the time keeps things exact!!)
For the NM SARS CoV 2 10X QUASR primer set:
Fam-FIP/BIP 16 Micromolar (µM)    -   32 µl each
LB/LF  8 Micromolar (µM)  -    16 µl each
F3/B3 2 Micromolar (µM)  -      4 µl each
          Anti-FIP-Q  24 Micromolar (µM)   - 48 µl 
48 µl DNAse/RNAse free water 

          if do basic for 12 reactions each +/- RTx   
         for: 2 waters, 2 RNA controls, 2 cell RNAs, 2 swabs, 2 bact lysates, 2 DNA controls (only have N, not Lamb Orf1a)
RowA - 18S rxns, RowB - 18S noRT, row C - E16S, row D E16S noRT, rowE - OL rxns, row F -OL noRT, rowG NM rxns,
row H use ends of NM 10ul each (instead of 20) H1, water, H2 N500, H3 and 4 R200, H5 OL 10ul, H6 OL N500, H7 OL R200
Clean with bleach first!!
Master Mixes for realtime amp data:  for 12 reactions each
2.0ul 10x buffer -  Isothermal buffer for Bst2.0           (x13 for all components for the 12 reactions)            (26ul)
1.12ul  20x primer mix                                     (14.6ul)                                      
1ul extra MgSO4, 100mM (for 5mM more - 7mM final in reaction  1.2ul for 6mM more 8mM final in reaction)       (13ul  or 15.6)      
2.8ul dNTP, 10mM                                                                                    (36.4ul)
0.8ul Bst2.0 (8units) or                                                                      (10.4)
( for A  master mixes RTx and RNAsin -out of this!?                             (10.4 + 6.5) 
1.6 ul SYBR-safe diluted 1/250 from stock solution.           (20.8) 
water + sample to 20ul final   (say 2ul of lysate, RNA or water per reaction)
             WATER  for rxns with 7mM and RTx No RNAsin) =7.88 x13 =102.44     WITHOUT RTx - 112.84
WATER  for rxns with 8mM and RTx No RNAsin) =7.68 x13 =99.84    WITHOUT RTx - 110.24
for BEI RNA dilute fresh 1000copy 1/10, so 100copies/ul.   200 copies/ rxn
                        B rxns (2B/3B) = 8.68x13=112.84. 

    10min 55degrees for RTx to start! change conditions on Prism
    **Again- Approximately Isothermal conditions, so get good traces:**
    **55 10min, 64 1min, then 'cycle' 10s 65 and 1:50s 64. (for imaging every 2 min)**
    **do 30 cycles with dissociation protocol clicked and 60 degrees...**

    Results
    things are coming up...  fingers crossed, after some messes during setup!  (was putting 8strip caps on first water column and sprayed out rxn master mixes from tube 12 (at least) ...
    ended up with column2 waters uncovered during the rest of samples' loading!  for the Cell RNAs used A2 from 27.10.20 for A-D5,6, and A1 from same date for E-G5,6... Then wasn't ready with swabs and worried about the polymerases in the buffer so long, so used C2 RNA from same date (27.10) 1ul for the 7,8 rxns in all rows.  For the bacterial lysate used the pink Ecoli from 2/5/2020  For the DNA control used old 500copies/ul N plasmid...  A2 and C2 were saliva samples extracted for surveillance screening (A became positive!)
    so, A-D(5/6) got A2 saliva RNA (maybe contam with N plasmid?)  and E-G(5/6) got the swab from that day A1
    then C2 1ul were saliva extracts (negative in october)
    experiment looks good, but we will see...
    

    OL clearly not so good as the NM! fastest control R200 for OL at Ct9 (21min) vs Ct14 noRT while NM is up by Ct4 (11min)
    18S still had quicker amp without RTx (Ct10=23min) than with (Ct13=29min), E16S cell RNA a bit slower without RT
    10ul reactions are ok still for signal esp NM