have + ready to go in freezer of hackuarium
but fam tag? in reaction to go, or just already done fluor is enough for tests?
(if the latter, then all ready...)

FAM tagged primer will just make more background, that won't increase signal

could see if syto81/hex channel will have better signal than eva green

First, Sam wants to see what the positive reaction looks like in his system
take solutions from yesterday's tubes 20180524 13/14/15
MoCo and 1/10 beef for him
(in hood-DEB)

see fluor ok

Then did run in the system (S.epi reactants from freezer about 75ul in it)  saw some signals come up (quickly).
then
put in T16
x2 tubes (not exactly same vols) vs water tube
fluor over 2000

https://www.dropbox.com/s/ilhujox35jfc3ib/20180525SamPost.png?dl=0

For Monday 28 will make 500ul Sepi
and x2 pork DNAFoils with resusp buffer and can use the pcr product as input!

from
http://pubs.rsc.org/en/content/articlehtml/2018/lc/c8lc00269j

worried also about further potential complications of pdms
some quotes:
It has been found that PDMS can release uncrosslinked oligomers from the curing process, and, on the other hand, it has been shown to absorb small molecules affecting the functionality such as biological assays.14 In addition, PDMS is highly permeable to gases and thus evaporation at micro- and nanolitre aqueous volumes can occur rapidly at increased temperature, e.g. during polymerase chain reaction for nucleic acid amplification. 

To achieve the benefits of fluorescence detection, with the most notably low limit of detection, fluorescent upconversion sensing has been developed for paper-based microfluidics.

suppl fig 2 esp interesting for fluor set up (almost epi??)
suppl fig 3 about getting signal 
suppl fig6 about filling (also use vacuum connection)