Set up for RNA extraction with the Monarch Kit again, with Tatiana.
Make 3 'saliva samples' (A, B, C)    2
2
2 saliva samples B and R (Benni and RA )
1 saliva spiked with BEI RNA (with RNAsin?).
2 cell RNAs (inner cheek cells)

Follow Monarch kit instructions, note details on sheet.
also following their saliva extraction guidelines  (no PK or DNAse! but equal vol of DNA/RNA soln) (protocol from NEB)
https://www.neb.com/protocols/2020/08/14/rna-extraction-from-saliva-using-the-monarch-rna-cleanup-kits
(should have tried an RTx- set too?!)
Details on printed page also for picture to add to drive.

For Bst2.0 +RTx 'Corona Detective' reactions make master mix:
(for each 20ul reaction)
2.0ul 10x buffer           (34ul)             
1.12ul* tagged primer mix   multiplex primers and quenchers.   (19.4)
1ul extra MgSO4, 100mM (for 5mM more - 7mM final in reaction)   (17)
2.8ul dNTP, 10mM      (47.6)
0.8ul Bst2.0 (8units)  (13.6)
0.5ul RTx (7.5units)    ( 8.5)
0.5ul RNAsin. (8.5)
water + sample to 20ul final   (say 2ul of extract or control/water per reaction

with extra 55degree 10min

with 16 reactions, made master mixes  x17
18-(all components above -doubleprimers) 7.86x17= 134
NM fluor primer mix _FAM-NM*FIP + RNaseP fluor primer mix. _hex-RP*LF  
Both quenchers 8.8ul for NM-FIP quench +4.4 for RP-LF quench, for water  -> 120.5ul

1,2 waters, 3,4 B extract, 5,6 R extract, 7,8  BEI RNA 100
9,10 older cheek cell RNA (R2 from 12.7), 11,12,  B extract + BEI RNA100, 13, 14 R extract +BEI RNA100, 15, 16 - N 50 copies. (old dilution)

For pcr machine - start with 10min at 55 degrees for *+* tubes, to give RTx a better chance to work (since low!)

For NM: 1.6uM for FAM tag FIP NM, so 2.4uM for quencher, 0.8uM for LF/LB, 0.2uM for F3/B3
For RNAseP: LF is the HEX tag, so 0.8uM LF and 1.2uM for the quench... 
base on 'ordinary double loop' mixes...
1.6uM FIP/BIP -     20 µl
0.8uM LB/LF -       10 µl 
0.2uM F3/B3 -         2.5 µl each
                               +5 ul water

great results, but not great timing (no probs for endpoint detection) with JOGL call...
Tatiana needs an extra bit of pipetting attention for small volumes (a couple false negative B tubes)

pics to go in drive