Notes de Rachel/Interns, Summer 2018 (51 notes)/20180821 Comet assay sterile vs bidistilled water and SYBR Safe vs Methylene blue
Revision as of 20:56, 18 November 2026 by DavidMontavon (talk | contribs) (1 revision imported: Import des notes de Rachel — lot 5/6)
Notes de Rachel / Interns, Summer 2018 (51 notes)
New materials produced:
- Saline 0.9% with sterile water (0.45 g in 50 ml of sterile water)
- Agarose 1.5% (0.375 g of agarose in the previous saline solution, with sterile water)
- Notes:
- We already had agarose 1.5% from a previous experiment
- Sterile water: made by reverse osmosis
Cell counting:
- sterile water: (26 + 37) equals 31 cells per square in average --> 310'000 cells in the sterile water falcon
- Need of 20'000 cells per tube --> 15 tubes for the sterile water
- Therefore, 1 ml/15 equals 62.5 ul per tube
- Bidistilled water: 25 cells per square --> 250'000 cells in the bidistilled water falcon
- Need of 20'000 cells per tube --> 12 tubes for the bidistilled water
- Therefore, 1 ml/12 equals 83.3 ul per tube
Preparation of the pads:
- Configuration of the pads: https://docs.google.com/spreadsheets/d/1mxpHjNSaEs1Flz8p0s5VI9-mn_Sjh86txncNkoV5YVE/edit#gid=1625783844
- Water first:
- In the two first columns, 500 ul of sterile water were put
- In the two last columns, 500 ul of bidistilled water were put
- Treated line:
- 17 ul of H2O2 3% put in the wells of the treated line, that had already 500 ul of saline --> 0.1% of H2O2
- This liquid was discarded (no bubbles seen)
- Washed twice (1 minute with the first wash) with saline water (sterile and bidistilled for the respective wells)
- Normal and treated lines
- Their 500 ul of saline have been discarded and 400 ul of PK buffer (sterile and bidistilled) have been put twice in the wells (sterile and bidistilled respectively)
- 75 ul of Proteinase K put in 1.6 ml of Proteinase Buffer Sterile
- 75 ul of Proteinase K put in 1.6 ml of Proteinase Buffer Bidistilled
- 400 ul of each of these solutions were put in the wells at 13:13 at room temperature, until 14:38
- The media were discarded and 750 ul of alkaline TBE was put for 5 minutes in the 8 wells (4 normal and 4 treated). This was done 2 times (2 washes)
- For all wells:
- 4 ml of 5X TBE were put in 16 ml of bidistilled water
- All media discarded
- 750 ul of this solution was put in each well for 5 minutes. This was done 2 times (2 washes)
- Put TBE 1X as the medium for the electrophoresis
- Put 4 pads on glass plates (from left to right):
- 1st plate: 4 pads Sterile Normal (SYBR Safe and Methylene blue differenciation will be made after)
- 2nd plate: 4 pads Bidistilled Normal (SYBR Safe and Methylene blue differenciation will be made after) Photo on whatsapp
- 3rd plate: 5 pads Sterile Treated (SYBR Safe and Methylene blue differenciation will be made after) Photo on whatsapp
- 4th plate: 5 pads Bidistilled Treated (SYBR Safe and Methylene blue differenciation will be made after) Photo on whatsapp
- Electrophoresis: 12V for 18 min, 5 mA
- Legends:
- USS: Untreated Sterile SYBR Safe;
- NSS: Normal Sterile SYBR Safe;
- TSS: Treated Sterile SYBR Safe;
- UBS: Untreated Bidistilled SYBR Safe;
- NBS: Normal Bidistilled SYBR Safe;
- TBS: Treated Bidistilled SYBR Safe
- Box 1: 3 pads TSS and 2 pads NSS;
- Box 2: 1 pad USS, 1 pad UBS, 3 pads TBS and 2 pads NBS
- Methylene blue staining:
- Put Methylene Blue
- Rince
- Put Iodine
- Wash with 1 ml of bidistilled water
- Wash with 1 ml of TBE
- Water first:
Observations:
AT UNIL
- For TSS
- Many comets, with small tails
- Note: next time, put more H2O2 in order to cover the pad.
- Put 20'000 cells per pad instead of 2’000 but the result is good too
- But a lots of clumps, maybe 10’000 would be better
- While using the application on the computer next to the microscope, mind clicking the image before saving to ensure that the image saved is the one you wanted.
- In the middle pad there are lots of cells so we could try to put methylene blue on it
- Many comets, with small tails
- For TBS plus de scotch
- We observe comets
- Work with bi-distilled water (from the Micropad startup) => No need of sterile water 😄
- Maybe test the distilled water from Migros (eau pour le fer à repasser)
- We observe comets
- For NBS (2 pads)
- We observe some tails, they seems even longer than the ones from TBS
- For NSS (2 pads) scotch se barre
- We observe tails that seems longer than the previous ones
- NSS looks better the NBS => maybe sth in the bi-distilled water breaks the cells. The comets seems smaller in NSS than NBS (visually)
Need to compare UBS and NSS to ensure that the bi-distilled water has an impact on the cell
- For UBS (1 pad)
- Cells look rounds, healthy
- GFP + phase
- Some looks weird, maybe apoptosis
- For USS (1 pad with bubbles)
- Cells look good
AT HACK
After a night in the fridge they look still super black/brown
- But slowly the dark color faint when shaked
Tried to find a filter at ~665nm for methylene blue
- Results:
- The untreated wells give nice cells, where their nuclei is colored
- But after several hours, the cells seem to shrink.
- On the other hand, the normal and treated wells do not give anything, we cannot see comets...
- The untreated wells give nice cells, where their nuclei is colored
NOTES:
Find a method to connect the two slides => maybe with the imprimante
Minimum 5 pictures are needed to make a comparison !
Maybe the comets were/seemed longer in the bidistilled thing because the water still contained ions and helped the DNA to migrate further