Notes de Rachel / First Notebook (126 notes)
To use new cell mRNA prep'd 12/7 for RNAseP in big beast and find out if Hex can show up in GMO detective detector.
First clean with 10% bleach. Then check that I have enough primers for all 6 sets of tubes (make more if needed - protect fluor from light)
Master mixes for x8 reactions RNAseP set (1,2 - water, 3,4 Cell mRNA, 5,6 BEIRNA 20, 7,8 Cell mRNA + BEIRNA 20
A BO +RTx with RNaseP (in cold for BO)
B Bst2.0+RTx with RNAseP
So, 6 master mixes in the end, all BO vs Bst2 comparisons: 2 for prism run with sybr safe, and 4 (quench/fluor RNAseP and NM+RNAseP) to simply be incubated at 65 degrees, with pictures on the 'GMO detective' detector every 5-10 minutes
Master Mixes for realtime amp data:
2.0ul 10x buffer - Isothermal buffer for Bst2.0 (x9 for all components for the 8 reactions) (18ul)
1.12ul* primer mix (10.1ul)
1ul extra MgSO4, 100mM (for 5mM more - 7mM final in reaction) (9ul)
2.8ul dNTP, 10mM (25.2ul)
0.8ul Bst2.0 (8units) or BstLarge Fragment (7.2)
for both master mixes RTx (7.2)
1.6 ul SYBR-safe diluted 1/250 from stock solution. (14.4)
water + sample to 20ul final (say 2ul of RNA or water per reaction)
WATER = 7.9 x9 = 71.1
A1 and B1 just RNAseP set for big beast as above,
A/B 2 and 3 as below, for fluor/quench detection...
- RNaseP fluor primer mix. _hex-LF for 1.2uM quench/rxn 2.2 ul in mastermix and water -> 83.3
- both of the primer sets together! fam and hex Both quenchers 4.4ul for NM-FIP quench +2.2 for RP-LF quench then water -> 68.8
to make fresh RNA dilutions 1/10 for 100copies/ul and 1/100 for 10 copies/ul
Again- Approximately Isothermal conditions, so get good traces:
65 2min, 64 1min, then 'cycle' 10s 65 and 1:50s 64. (for imaging every 2 min)
do 35 cycles again with dissociation protocol clicked and 60 degrees...
for the 2 and 3, just 65degrees and pics
A2 then A3, then B2 then B3 for pics
7min, 15min, 20min, 25min, 30min, 35min, 40min, 45min... (then pcr machine for iGEM group...)
B2 first up by 25min, and BO first up only at 40min... not too bad?? (RNAseP primer set was slow.)
RTx should be used at 0.5ul in 25ul reaction?
I can use less! should try 0.4/20ul reaction...
real time results not too bad...