Difference between revisions of "Open Source Bioreactor"
Line 71: | Line 71: | ||
=== Dynamic gas Mix === | === Dynamic gas Mix === | ||
+ | |||
+ | The Anemometer board addresses the need to control the bioreactor atmosphere. It dispose of 4 flow measurement channels to dynamically analyze the input and output flows of gas in the reactor. It allows to obtain a desired mix out gas bottles with pure content (CH4, N2, CO2,...) and potentially to operate the system in anaerobic conditions by ensuring a constant overpressure. Though it, of course, requires a bit more of material both electronic and fluidic. | ||
== External Resources == | == External Resources == |
Revision as of 20:36, 22 November 2016
The Project
History
List of contributors
Project Coordinators
Pr. Luc Patiny, ISIC EPFL-UNIL, Lausanne, CH Pr. Julien Wist, DARMN Research Group, Univalle, Cali, CO Pr. Janeth Sanabria, GAOX Research Group, Univalle, Cali, CO Quentin Cabrol, MSc Micro and Nanosystems EPFL
Current Collaborators, on Oct 2016
Clément Chenevas, Life Science Student EPFL : operation of Bioreactor v3 @ Univalle Alice Leydier, Life Science Student EPFL : operation of Bioreactor v3 @ Univalle Alexandre Gubert, Mechanical Student EPFL : mechanical Design of Bioreactor v3 @ Univalle Daniel K Michael
Past Collaborators Emilien Eric Marco Schukraft (1 more ?) David Lambalet Samuel Benketaf Raffael Tschui Gabriel Laupré Gael Grosch Oliver Peric
Add project contacts here with roles in the project.
Concept
This project is a collaboration between Univalle (Universidad Del Valle - Colombia) and EPFL (Polytechnical school of Lausanne - Switzerland). The goal was to build an Open Source Bioreactor that everyone could assemble and use, from their backyard to the universities around the world.
This Bioreactor can be used for many applications, such as growing bacterias in anaerobic conditions, with an automatised interface. The temperature, pH, conductometry, feeding and flow of gas going in the reactor can be controlled. All the parameters are stored in a card for future use and can be changed or viewed remotely.
Once the Bioreactor is build, all you have to do is choose the conditions of your experiment (pH, temperature, time of sedimentation, flow of gas), and the Bioreactor will do the rest for you !
Central Unit
Requirements Specifications
Mechanical Design
Electrical Design
Embedded Software
Remote Control & Visualizer
User Manual
Bill of Materials
Extension Modules
pH regulation and conductometry
The Bioreactor contains a pH board, that can be used with a standard gel probe containing reference electrode and a BNC/RCA (Cinch) 2-Wires output. You can choose to regulate or not the pH of your solution, by changing the pH state. In order to regulate the pH, the target pH should be set and solutions of acid and base should be prepared.
Another board is dedicated for the measure of the conductometry.
Dynamic gas Mix
The Anemometer board addresses the need to control the bioreactor atmosphere. It dispose of 4 flow measurement channels to dynamically analyze the input and output flows of gas in the reactor. It allows to obtain a desired mix out gas bottles with pure content (CH4, N2, CO2,...) and potentially to operate the system in anaerobic conditions by ensuring a constant overpressure. Though it, of course, requires a bit more of material both electronic and fluidic.